Inline Reactor Sampling Systems SRS Series
SWISSFLUID REACTOR SAMPLING SYSTEMS SRS SERIES
For safe representative and closed sampling of aggressive or toxic media out of reactors and tanks – quick, reliable, without process interruptions.
m will be assembled easily and complete, just according to the given specification.
MODULAR DESIGN
Reactor Sampling Systems are available as basic versions such as SRS-P (PFA-lined) resp. SRS-P-P, PFA-lined with air driven diaphragm pump.
The systems operate, i.e. extract the required sample by means of vacuum or under pressurized conditions. In addition to the basic units, a large variety of accessories and options can be selected and the syste
MAIN FEATURES
- Robust construction, assuring easy and safe operation at any time
- Simple extension with additional components resp. upgrading of existing systems
- Main valve standard 1” – 150lbs, PFA-lined, manually operated
- 2-hole mounting plates for easy installation of additional valves or connections
- Various reserve connections
- Ball seat made of Perfluor, for wear-free and reliable sealing of the PTFE hollow ball
- Flange connections ac. To DIN or ANSI
- CE Logo Conformity according to European Pressure Equipment Directive 97/23/EC (PED)
OPERATING CONDITIONS
- Operating pressure main valve 16 bar
- Operating pressure sight glass 10 bar
- Temperature range main valve -30°C up to +200°C (depending on lining material)
- Vacuum (suction head approx. 3m) 500 mbar abs.
- Sampling volume standard 150/250 ml
TESTING / MARKING
- Pressure- and tightness testing acc. to EN 12266-1, leakage rate A, and spark testing at 35 KV to assure lining integrity.
- Marking of system components acc. to EN 19.